Environmental Specifications
|
Commercial
|
Rugged Level 2
Convection Cooled
|
Rugged Level 3
Conduction Cooled
|
| Operational Temperature |
0°C to +55°C
(300 LFM airflow)
@ 0 to 10,000’ |
-40 to +70ºC
(600 LFM airflow)
@ 0 to 30,000’ |
-40°C to +85°C (Card Edge) @ 0 to 60,000’ |
| Storage Temperature @ Relative Humidity |
-40°C to +85°C
(10% to 95% non-condensing) |
-55°C to +100°C
(5% to 95% non-condensing)
|
-55°C to +125°C
(0% to 95% non-condensing)
|
Relative Humidity (Operational)
|
10% to 95%
(300 LFM airflow)
non-condensing
|
5% to 95%
(600 LFM airflow) non-condensing
|
0% to 95%
non-condensing |
Shock (Operational)
|
20g, 11 1/2 ms sine pulse
|
20g, 11 ms 1/2 sine pulse
|
40g, 11 ms 1/2 sine pulse
|
Vibration (Sine) (Operational)
|
sine 2g peak
15 to 2000 Hz
|
sine 10g peak
15 to 2000 Hz
|
sine 10g peak
15 to 2000 Hz
|
Vibration (Random) (Operational)
|
0.003g2/Hz from 15 to 2000 Hz
|
0.04g2/Hz from 15 to 2000 Hz
|
0.1g2/Hz from 15 to 2000Hz per MIL-STD-810E Fig 514.4 - 8 "12g RMS
|
Conformal Coating
|
No |
Yes |
Yes |